Kestrel 5700/Ruger 5700 Ballistics Meter to Kestrel 5700 Elite/Ruger 5700 Elite Upgrade - Download Only

$300.00

Firmware upgrade that can be installed on a Kestrel 5700 or Ruger Kestrel 5700 Ballistics Meter, converting it into a full Kestrel 5700 Elite model (Ruger Kestrel 5700 will be upgraded to a Ruger Kestrel 5700 Elite) with its more advanced extreme long range features.

Please note: Selecting this purchase means that you currently already have a PC connection accessory (Bluetooth dongle or USB Transfer Cable). If you do not, you will need to purchase product with connection accessory options.

Availability: In stock
SKU
0857U2
Please fill out the selections below to help us ensure that you're getting the most accurate product

Maximum 20 characters

Maximum 100 characters


 FREE US SHIPPING

Kestrel 5700/Ruger 5700 Ballistics Meter to Kestrel 5700 Elite/Ruger 5700 Elite Upgrade - Download Only Overview


Elevate your shooting experience with the Kestrel 5700 or Ruger Kestrel 5700 Ballistics Meter by upgrading to the advanced Kestrel 5700 Elite model. This firmware upgrade unlocks the full potential of your device, enhancing it with extreme long-range shooting features and capabilities.

Key Benefits of the Upgrade:

  • Advanced Ballistics Features: Gain access to sophisticated ballistics calculations and custom drag models, enabling more accurate long-range shots.
  • Enhanced User Interface: Enjoy a more intuitive and user-friendly interface, making it easier to navigate through advanced settings and features.
  • Extended Range Capabilities: Push the limits of your shooting accuracy with features specifically designed for extreme long-range shooting scenarios.
  • Customizable Options: Personalize your device with customizable ballistic profiles and environmental settings tailored to your specific needs.

Compatibility:

  • Kestrel 5700: This firmware upgrade will convert your Kestrel 5700 into a Kestrel 5700 Elite, providing you with all the advanced features of the Elite model.
  • Ruger Kestrel 5700: Upgrade your Ruger Kestrel 5700 to a Ruger Kestrel 5700 Elite, unlocking enhanced functionalities designed for the most demanding shooters.

Important Installation Information:

  • Kestrel LiNK Ballistics App: Upgrading your firmware is now easier than ever with the Kestrel LiNK Ballistics app, available on both iOS and Android. The upgrade process is straightforward and user-friendly, allowing you to quickly enhance your device without any hassle.

Experience the full power and precision of the Kestrel 5700 Elite with this essential firmware upgrade. Whether you're a competitive shooter, a hunter, or a tactical professional, this upgrade will provide you with the tools you need to achieve unparalleled accuracy and performance.

PLEASE NOTE: The emailed file will be delivered within 48 hours and is NOT sent between 2pm Friday and 9am Monday.

  • Aerodynamic Jump Correction
  • Applied Ballistics Custom Drag Models
  • *Connect with LiNK Compatible Range Finders
  • Coriolis Correction
  • Create and store 10 Targets
  • Create and store up to 30 Gun/Bullet Profiles
  • G1/G7 Drag Models
  • Muzzle Velocity Calibration
  • Range Card
  • Spin Drift Correction
  • Supports Mil, MOA, Clicks
  • Subsonic Range Drop Scale Factor Calibration
  • Standard and Night Vision Preserving Backlight
  • Target Range Estimator
  • Zero Offset

    • * Applies to LiNK models only

The specs on this page relate to all Kestrel 5 series meters. Just because a measurement is listed in this chart does not necessarily mean that it is included with all meters. To see a listing of all measurements and features for this meter, please click on the In-Depth tab above.

SENSORS
SENSORS ACCURACY RESOLUTION SPECIFICATION RANGE NOTES
Wind Speed | Air Speed Larger of 3% of reading, least significant digit or 20 ft/min Speed 0.1 m/s
1 ft/min
0.1 km/h
0.1 mph
0.1 knots
1 B*
0.1 F/S*
0.6 to 40.0 m/s
118 to 7,874 ft/min
2.2 to 144.0 km/h
1.3 to 89.5 mph
1.2 to 77.8 knots
0 to 12 B*
2-131.2*
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH|7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller
Ambient Temperature 0.9 °F
0.5 °C
0.1 °F
0.1 °C
-20.0 to 158.0 °F
-29.0 to 70.0 °C
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.
Relative Humidity 2%RH 0.1 %RH 10 to 90% 25°C noncondensing To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.
Pressure 1.5 hPa|mbar
0.044 inHg
0.022 PSI
0.1 hPa|mbar
0.01 inHg
0.01 PSI
25°C/77°F
700-1100 hPa|mbar
20.67-32.48 inHg
10.15-15.95 PSI
Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.
Compass
1/16th Cardinal Scale
0 to 360° 2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout.

CALCULATED MEASUREMENTS
MEASUREMENT ACCURACY (+/-) RESOLUTION SENSORS EMPLOYED
Air Density 0.0002 lb/ft3
0.0033 kg/m
0.001 lbs/ft3
0.001 kg/m3
Temperature, Relative Humidity Pressure
Air Flow 6.71% 1 cfm
1 m3/hr
1 m3/m
0.1m3/s
1 L/s
Air Speed, User Input (Duct Shape & Size)
Altitude typical: 23.6 ft/7.2 m
from 750 to 1100 mBar
max: 48.2 ft/14.7 m
from 300 to 750 mBar
1 ft 1 m Pressure, User Input (Reference Pressure)
Barometric Pressure 0.07 inHg
2.4 hPa|mbar
0.03 PSI
0.01 inHg
0.1 hPa|mbar
0.01 PSI
Pressure, User Input (Reference Altitude)
Crosswind & Headwind/Tailwind 7.1% 1 mph
1 ft/min
0.1 km/h
0.1 m/s
0.1 knots
Wind Speed, Compass
Delta T 3.2 °F
1.8 °C
0.1 °F 0.1 °C Temperature, Relative Humidity Pressure
Density Altitude 226 ft
69 m
1 ft 1 m Temperature, Relative Humidity Pressure
Dew Point 3.4 °F
1.9 °C
15-
95% RH. Refer to Range for Temperature Sensor
0.1 °F
0.1 °C
Temperature, Relative Humidity
Evaporation Rate 0.01 lb/ft2/hr
0.06 kg/m2/hr
0.01 b/ft2/hr
0.01 kg/m2/hr
Wind Speed, Temperature Relative Humidity Pressure, User Input (Concrete Temperature)
Heat Index 7.1°F
4.0°C
0.1 °F
0.1 °C
Temperature, Relative Humidity
Moisture Content | Humidity Ratio (“Grains”) 4.9gpp
.7g/kg
0.1 gpp
0.01 g/kg
Temperature, Relative Humidity Pressure
Probability of Ignition (PIG) PIG Accuracy dependent on proximity of inputs to reference table steps. 10% Temperature, Relative Humidity
THI (NRC) 1.5 °F
0.8 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity
THI (Yousef) 2.3 °F
1.3 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity
Relative Air Density .0.3% 0.1% Temperature, Relative Humidity Pressure
Wet Bulb Temperature - Psychrometric 3.2 °F
1.8 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity Pressure
Wet Bulb Temperature - Naturally Aspirated (NWB TEMP) 1.4 °F
0.8 °C
0.1 °F
0.1 °C
Wind Speed, Temperature Globe Temperature, Relative Humidity, Pressure
Wind Chill 1.6 °F
0.9 °C
0.1 °F
0.1 °C
Wind Speed, Temperature
 
ADDITIONAL PRODUCT INFO
Display & Backlight Multifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight.
Response Time & Display Update Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes.
Data Storage & Graphical display Min/Max/Avg History Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points.
data Upload & Bluetooth Data Connect Option Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC).
Clock/Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Auto Shutdown User-selectable – Off, 15-60 minutes with no key presses.
Languages English, French, German, Spanish.
Certifications CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards.
Origin Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery Life AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use.
Shock Resistance MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
Sealing Waterproof (IP67 and NEMA-6)
Display & Battery Operational Temperature Limits 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading.
Storage Temperature -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
Size & Weight 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included)


Models & SKUs:

  • Kestrel 5700 Ballistics Weather Meter with LiNK: 0857BLTAN
  • Ruger Kestrel 5700 Ballistics Weather Meter with LiNK: 0857BLBLK-RUG

Kestrel Ballistics 5 Series Troubleshooting Documents

Guidance on submitting a tax exempt order through the website

Product Questions

You cannot upgrade the 5700 Elite as it doesn't have the processing power to run the analysis. You can upgrade your 5700X to include WEZ for $100. Please connect your unit to the Kestrel LiNK Ballistics app and you will see a pop up. Follow the prompts in the app to upgrade it.

... Permalink